The following is a selection of the most popular hardwired fire alarm systems we supply. We have conveniently organised these into categories to ensure all compatible panels & field devices are grouped together.
Infinity ID2 2 Wire Fire Alarm System
- Ability to wire in Radial or Loop modes (selectable on panel).
- No need for end-of-line devices and ability to spur from any device.
- Panel shows exact devices in fire/fault (e.g. "Main Office", "Bedroom 1", etc).
SmartConnect Touchscreen Addressable System
- 4.3 inch colour touch screen display.
- Remote monitoring via a desktop PC or smartphone via the cloud.
- Built-in network facility.
Fike Twinflex 2 Wire Fire Alarm System
- Single radial wired for each zone supporting detectors, call points & sounders.
- Multipoint detectors with 7 different modes of detection & integral sounder.
- Checkpoint alarm confirmation technology to help reduce false alarms.
Advanced MxPro 5 & Hochiki ESP Addressable
- Choice of 1, 2, 4 or 8 loop panels.
- Networkabled systems with up to 200 nodes.
- High-performance Hochiki ESP devices, progarmmed via hand-held programmer.
Infinity Conventional Fire Alarm System
- Economical conventional system.
- 2, 4 or 8 zone starter kits available to reduce costs.
- 4-8 zone panels have 4 sounder circuits.
Apollo AlarmSense 2 Wire System
- Choice of C-Tec, Kentec or Haes panels.
- Ideal solution for small installations, including HMOs.
Eaton Ultra BiWire Fire Alarm System
Morley-IAS DX Connexion Fire Alarm System
CAST Addressable System by C-Tec
We also supply a comprehensive range of wireless fire alarm systems alongside products from most major fire alarm manufacturers.
Types of fire alarm system
Broadly speaking there are 3 types of fire alarm system namely; conventional, twin-wire and addressable. Each type can form a compliant system however there are key difference in how they are installed (both in term of wiring and programming) and how they function (both in terms of alarm indication and programming features).
The following table highlights a comparison between these types of system.
Conventional Fire Alarms Systems | 2 Wire Fire Alarm Systems | Addressable Fire Alarm Systems | |
---|---|---|---|
Standards | Fully complies with all relevant BS and EN standards. | Fully complies with all relevant BS and EN standards. | Fully complies with all relevant BS and EN standards. |
Panel Sizes | Fire alarm panel available in 1, 2, 4, 6 or 8 zones. | Fire alarm panel available in 2, 4 or 8 zones. | Fire alarm panel available in 4 zones. |
Wiring | Detectors and call points are connected on a pair of wires for each zone, warning devices (sounders & flashers) for all zones are connected on a separate pair of wires. | All devices (detectors, call points, sounders and flashers) are connected on the same pair of wires for each zone. | All devices (detectors, call points, sounders and flashers) are connected on a single pair of wires for all zones, this is typically wired in a complete loop returning to the panel (similar to an electrical ring main). |
Alarm Identification | During an alarm the panel will identify the zone containing the detector which was triggered. | During an alarm the panel will identify the zone containing the detector which was triggered. | During an alarm the panel will identify the exact detector which was triggered (a 20 character label can also be specified for each device, for instance 'Bedroom A' which will be shown during an alarm). |
Special Features | Alarm and fault history, cable break and short circuit protection and system monitoring. |
Need help choosing a fire alarm system?
Call our experinced team on 01792 983 170 or email us via sales@discountfiresupplies.co.uk.